Overview

What is an access control system?

An access control system decides who may open which door and when. People present a credential such as a card, fingerprint, face or mobile phone to a reader, the controller checks their permissions, and the electric lock releases only if they are allowed.

Unlike keys, credentials can be issued and cancelled instantly, and every entry or attempt is logged. iTime Solutions installs readers, controllers, electric locks and exit devices and configures access levels by person, door and time schedule.

When does a building need access control?

You need it when keys are being copied, lost or shared, when you must restrict areas such as server rooms, stores, finance offices or labs, or when you need a record of who entered. It is also useful in Egyptian offices, schools, clinics, factories and residential compounds where many people with different roles share one site.

  • Restrict sensitive rooms to named staff.
  • Give contractors and visitors temporary access that expires automatically.
  • Cancel a lost card in seconds instead of changing locks.
  • Prove who entered a door at a given time.

What are the parts of the system?

  • Credentials: proximity or smart cards, fingerprints, face recognition or mobile credentials.
  • Readers: mounted at the door, sometimes combining two methods such as card plus PIN for higher security.
  • Controllers: the unit that stores permissions and makes the decision, often continuing to work if the network is down.
  • Locks and exit devices: electric strikes, magnetic locks or motorised locks, plus exit buttons and door contacts.
  • Management software: where you enrol people, set schedules and view reports.
  • Power supplies with battery backup so doors behave safely during outages.

Which credential type should you choose?

CredentialStrengthsPoints to consider
Card or tagSimple, cheap to issue, fastCan be lost or shared
FingerprintTied to the person, no card to carryWorn or dirty fingers can fail; privacy policy needed
Face recognitionContactless, quick at busy entrancesNeeds good lighting and correct placement
Mobile credentialNo hardware to issue, easy to revokeDepends on staff using their phones

Many sites mix methods: cards at general doors and fingerprint or face plus PIN for sensitive rooms.

Think about visitors and shift workers early. Visitors can receive temporary cards or time-limited codes, contractors can be restricted to certain doors and hours, and shift staff can be given schedules that match their rota, so doors open only when they should.

How does it work with fire alarm, CCTV and time attendance?

The system can integrate with other building systems. Wired to the fire alarm, it releases doors automatically when the alarm activates so people can leave safely. Linked with CCTV, an entry event can bring up the matching video. The same readers can also record attendance and feed payroll reports, so you do not need separate clocking machines.

Life-safety rules matter: exit routes must always remain usable, and lock choices should be agreed with the building's fire and safety requirements.

How does an access control project run, and what does it cost?

  1. Survey: list doors, door type, frame material, traffic and who needs access where.
  2. Design: choose credentials, readers, lock type per door and the access levels.
  3. Installation: cabling, door hardware, controllers, power and network.
  4. Configuration: enrol users, schedules and reports; link to fire alarm, CCTV or attendance.
  5. Testing and training: test every door and the fire release, then train administrators.

Cost is by quotation and depends on the number of doors, door and frame type, reader technology, lock type, cable runs, software and users, and integrations. We do not publish fixed prices.

Doors are the hardest part of any project. A glass door, a fire-rated door and a double door each need a different lock and fitting method, which is why the door survey comes before any equipment is chosen.

What mistakes should you avoid?

  • Choosing the lock before checking the door, frame and fire-exit requirement.
  • Putting every door on the same access level.
  • Forgetting battery backup so doors fail unpredictably in a power cut.
  • Not removing leavers' credentials promptly.
  • Using readers in direct sun or dust without suitable protection.

For maintenance, check door closers and locks, test the fire release periodically, back up the database and keep the software updated. iTime Solutions supports installed systems for sites in Cairo and across Egypt.

Questions and answers

What affects the cost of an access control system?

Cost depends on the number of doors, door and frame type, reader technology, lock type, cable runs, software and users, and any integration with fire alarm, CCTV or attendance. We quote after a door-by-door survey. Door type often changes the price more than the reader does.

How long does installation take?

It depends on the number of doors, cable routes and door preparation. A few doors can be done quickly, while large buildings take longer. We schedule work to keep the site accessible and agree dates after the survey. Door preparation by other trades can affect timing.

Can it be added to existing doors and locks?

Often yes. Many doors can take an electric strike or magnetic lock, but glass, fire-rated and metal doors need checking. We inspect each door and recommend the right lock instead of forcing a standard one. We note any door that needs a different lock before quoting.

What happens if the power or network fails?

Controllers normally keep permissions locally and continue working without the network. A battery backup keeps readers and locks running briefly, and the failure mode, locked or unlocked, is chosen per door for safety. We test this by cutting power and the network during commissioning.

Which is better, fingerprint or card?

Neither is best everywhere. Cards are simple and fast but can be shared, while fingerprints tie access to the person. Many sites use cards for general doors and fingerprint or face plus PIN for sensitive rooms. Your security policy and user numbers also guide the decision.

Can doors open automatically during a fire?

Yes, when the system is wired to the fire alarm. Doors in escape routes release when the alarm activates. We design this together with the building's safety requirements and test it before handover. The fire release is tested again during periodic maintenance.

What is the most common mistake with access control?

Not managing credentials after installation. Leavers keep working cards, groups get too broad and the log is never reviewed. Assign an owner, review permissions regularly and remove access promptly when roles change. A short monthly review is usually enough to keep it tidy.

Tell us about your project.

Book a free site survey and get a clear proposal with scope, timeline and cost.